June 2007 Replacing or adding voice processing boards
1005r Server Maintenance and Diagnostics 171
Figure 47: Full-height PCI card
12 Remove the rear retention screw (B) as shown in the previous
diagram.
13 Replace the card and tighten the screws. Make sure the red power
cable to the full-size PCI riser card is not pinched.
14 Reconnect the 3-drop CT bus cable (high capacity configuration
only).
15 Turn the PCI riser card right-side up.
16 Arrange the PCI riser assembly short red power cable inside the
riser assembly as shown in the following illustration to avoid
pinching the cable when you put the riser assembly into the chassis.