RAID operations Standard 1.10
150 CallPilot
1 Restart the server and enter the Ctrl+M utility when prompted
during system bootup.
2 From the Management menu, select Objects and press Enter.
3 Select Objects > Physical Drive and press Enter.
4 Select FAIL Drive for the drive that is online (A01-1-Onln).
Result: The drive shows as failed.
5 Select the second drive (previously taken offline as the backup drive
and marked failed) and make it ONLINE. Ignore the warning
message.
Result: The second drive is marked ONLINE and the first drive is
marked failed.
6 Exit the utility and press Ctrl+Alt+Delete to reboot the server.
Result: The system boots up to the original configuration before the
PEP installation.
7 When the system is fully booted, open the Windows MegaRAID
console and rebuild the failed drive using the same process
described in “To synchronize the RAID after a successful PEP
installation,” on page 149.
Result: The system is now in the original configuration.
ATTENTION
Do not use the Power Console for the following procedure,
or data corruption can occur.