Chapter 2 CLI Command Summary 129
Reference for the Contivity VPN Switch Command Line Interface
Default
If a warning level is not given, then only alert and warning problems are shown,
equivalent to:
show health warnings
Command mode
Privileged Exec
Response
See the example for output from this command.
Next command mode
Privileged Exec
Related commands
audible alarm
Example
CES#show health warnings
Alert: LAN on slot 2 Interface 1. Device fei1 down
Alert: Auto backup servers. Can't backup to 12.33.44.123
Alert: Voltage 2.5 VA. Voltage out of range
Alert: Chassis Fan. Fan not functioning
Warning: Hard Disk 1. Device /ide1/ not available
Warning: SNMP Servers. Server not configured
This example shows the type of output that is displayed when alerts and warning
messages are requested by the show health command.