46 Common TOPS VSN log messages (020A)
TOPS VSN Log and alarm messages
0001/0031
Message:
[PRU_NAME] could not interpret a triple read from the SDM.
Table name = [table_name]
Tuple ID = [tuple_name]
"Diagnostic String1"
"Diagnostic String2"
Description:
This log indicates an error in interpreting a field within the
specified tuple.
Action: Re-edit the tuple and verify that the fields are all of the correct type.
0001/0032
Message:
[PRU_NAME] was attempting to perform an SDM "notification
Registration" and failed.
Table name = <table_name>
"Diagnostic String1"
"Diagnostic String2"
Description:
This log indicates the SDM Notification server may be down or
faulty.
Action:
Ensure that the SDM Notification Server is in a working state. If the
problem persists, retain all of the information regarding the problem and contact
your NT representative.