Page 414 of 906 NT6D80 MSDL card
553-3001-211 Standard 3.00 August 2005
A newly configured MSDL automatically enters the manually disabled state.
An operating MSDL can be manually disabled by issuing the
DIS MSDL x
command in LD 37 (step 1 in Figure 87).
Entering the
DIS MSDL x command in LD 37 moves the card to manually
disabled status and stops all system communication with the card (step 5 in
Figure 87).
Manually enabled
When the card has been manually disabled, re-enable it with the
ENL MSDL
x
command in LD 37 (step 2 in Figure 87).
Figure 87
MSDL states
Manually disabled
Enabled
12
34
5
System disabled
553-5435
Przeglądanie stron 413